Flow meter accessories
2/2-way solenoid valve
made of brass
Description:
The 2/2-way solenoid valve seals off the air supply to the double diaphragm pump. It is controlled via the relay module.
Material: Brass
Features & advantages
Connection type: 3/8" female thread
3-way motor/slow connection cable
for the RM10 relay module
Description:
The connection cable is used for direct connection between the RM10 relay module and the respective motor.
Special lengths are available on request
Features & advantages
Cable length: 0.5 m
Voltage: 230 V
Frequency: 50 Hz
PPO
1 1/4" FEMALE THREAD
FPM seal
Barrel pump connection
made of plastic for the ST 10 and SL10 flow meters
Description:
The drum pump connection is required to connect the ST 10 / SL10 flow meters to a drum and container pump. To connect the LM10 / UN 10 flow meter to a drum pump, the connection with the conductive drum pump connection in the PPS version is required.
Materials PPO / PPS
Features & advantages
Connection: 1 1/4" female thread to 2" male thread
Seals: FPM and FPM - FEP
Explosion protection
Stainless steel
1 1/4" - 1 1/4" IG
Barrel pump connection
made of stainless steel for VA 10 Ex flow meters
Description:
The drum pump connection is required to connect a VA 10 flow meter to a drum and container pump.
Material stainless steel
Features & advantages
Connection: 1 1/4" female thread - 1 1/4" female thread to 1 1/4" male thread
Seals: PTFE
PP
PTFE seal
Barrel pump connection
made of PP for the HDO 250P flow meter
Description:
The drum pump connection is required to connect the HDO 250P/HDO 250 flow meter to a B70V or HD-E progressive cavity pump. To connect the HDO 250 Ex version flow meter to an eccentric worm-drive pump, it is necessary to use the stainless steel version of the conductive drum pump connection.
Materials: PP / stainless steel
Features & advantages
Connection: 1" male thread to 1 1/4" female thread / 1" male thread to 1 1/2" female thread
PTFE seals
Explosion protection
Base counter
for type LM10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be installed separately from each other if there are large distances between the measuring and control points or if the installation locations in the system are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: PPS
Features & advantages
Measuring chamber: LCP
Seals: FEP
Magnet material: BaFE / MS / stainless steel (1.4401)
Type of protection: II 2G Ex h IIB Gb X
Explosion protection
Base counter
for type VA10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be installed separately from each other if there are large distances between the measuring and control points or if the installation locations in the system are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: Stainless steel
Features & advantages
Measuring chamber: Stainless steel
Seals: FEP
Magnet material: PTFE encapsulated
Type of protection: II 2G Ex h IIB Gb X
Base counter
for type ST10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be installed separately from each other if there are large distances between the measuring and control points or if the installation locations in the system are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: PPO
Features & advantages
Measuring chamber: PPO/PPS
Seal: FPM
Magnet material: Ba/Fe / PA / stainless steel
Base counter
for type SL10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be installed separately from each other if there are large distances between the measuring and control points or if the installation locations in the system are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: PPO
Features & advantages
Measuring chamber: PPO/PPS
Seal: FPM
Magnet material: PPS encapsulated
Explosion protection
Base counter
for type UN10
Description:
The basic meter is required for decentralised installation and external data evaluation. The individual modules (basic counter, operating unit, relay module, etc.) can be installed separately from each other if there are large distances between the measuring and control points or if the installation locations in the system are difficult to access. Data transmission between the components is established without complicated wiring by means of plug connections via a data cable and a protective cover / pulse converter.
Material: PPS
Features & advantages
Measuring chamber: LCP
Seals: FEP
Magnet material: PPS encapsulated
Type of protection: II 2G Ex h IIB Gb X
PP
Combi plate
for the ST10, SL10, LM10, UN10, VA10, HDO 080, HDO 120; HDO 200, HDO 250, HDO 400, HDO 500 series
Description:
The combination plate is required to fix the operating unit. It can be used to fix the modules to the wall or as a heat protection plate between the base meter and the modules.
Material: Polypropylene (PP)
Communication module KM10K (complete version)
for the ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500 series
Description:
The communication module enables communication with other control units.
Cable glands are integrated
Features & benefits
Analogue output (0-20mA, 4-20mA, 0-10V)
Pulse and alarm output
RS485 interface
Connection cable motor/slow 1-fold
for the RM10 relay module
Description:
The connection cable is used for direct connection between the RM10 relay module and the respective motor.
Special lengths are available on request
Features & advantages
Cable length: 0.5 m
Voltage: 230 V
Frequency: 50 Hz
Control unit
for series ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500
Description:
Evaluation electronics with touchscreen for operating the flow meter. The operating unit is used to analyse the pulses and shows them as a quantity on the digital display.
Types: BE 10 / BE 10V (encapsulated electronics)
Explosion protection
Control unit
for series ST10, SL10, VA10, HDO080, HDO120, HDO200, HDO250, HDO400, HDO500
Description:
Evaluation electronics with touchscreen for operating the flow meter. The operating unit is used to analyse the pulses and shows them as a quantity on the digital display.
Types: Ex-BE 10B / Ex-BE 10BV (electronics encapsulated)
Explosion protection
Control unit
for the series for LM10, UN10, VA10, HDO080Ex, HDO120Ex, HDO200Ex, HDO250Ex, HDO400Ex, HDO500Ex
Description:
Evaluation electronics with touchscreen for operating the flow meter. The operating unit is used to analyse the pulses and shows them as a quantity on the digital display.
Types: Ex-BE10C / Ex-BE10CV (electronics encapsulated)
Explosion protection
5 m
Explosion protection
5 m
PP
Double nipple
in the PP version
Description:
The double nipple is required as a connection between the solenoid valve and hose connection.
Material: PP / brass / stainless steel
Features & advantages
Connection type: 3/4" AG to 1 1/4" AG
Double nipple stainless steel
for flow meters
Description:
The double nipple is required as a connection between the flow meter and the hose line.
Material: Stainless steel
An additional spacer ring Art. No. 0231-545 is required
Features & advantages
Connection type: 1" AG x 1 1/2" AG
Extension cable
for the RM10 relay module
Description:
The extension cable is used to extend the connection on the RM10 relay module.
Special lengths are available on request
Features & advantages
Cable length: 5 m
Voltage: 230 V
Frequency: 50 Hz
4-pole
PPO
DN 32 / PN 10
Seal FPM
Flange connection
made of plastic for flow meters ST10 / SL10
Description:
The flange connection is required to connect the ST 10 / SL10 flow meters to a pipework system. To connect the LM10 / UN 10 flow meters to a pipework system, the connection with the conductive flange connection in the PPS version is required.
Materials PPO / PPS
Properties & advantages
Flange connection: DN 20 / PN 10
Seals: FPM and FPM - FEP
Explosion protection
Stainless steel
DN 25 / PN 6
Flange connection
made of stainless steel for VA10 flow meters
Description:
The flange connection is required to connect the VA 10 flow meter to a pipework system. The connection is conductive and can therefore be used in potentially explosive environments.
Material: Stainless steel
Features & advantages
Flange connection: DN 25 / PN 6, DN 32 / PN 6, DN 32 / PN 10, DN 40 / PN 10