Vacuum regulator C 2213
The C 2213 is designed for both individual and parallel use of several vacuum regulators in battery operation. A heated droplet separator is optionally available for use on gas drums on the pressure side.
Features & benefits
- Throughput capacity with chlorine gas: up to 10 kg/h
- Residual pressure protection: Prevents the chlorine cylinder from being completely evacuated to prevent corrosion caused by moisture in the air
- Filter: To protect the valve from dirt particles from the chlorine cylinder or the connection area
- Cylinder pressure gauge: To display the pressure in the chlorine tank
- Simultaneous withdrawal: For largely uniform chlorine withdrawal from several chlorine cylinders in battery operation
- Flow limiter: To prevent cylinder icing due to excessive chlorine withdrawal
- Gas filter
- Compact design
- Available with all standard gas connections
MATCHCODE: | 0204D11N00B4L2A |
---|---|
Funktionen:: | Der Vakuumregler dient zur Reduzierung des Gasdrucks vom |
Typ:: | C 2213 |
Eingang:: | Überwurfmutter BSW 1" - DIN 477 |
Dosieranschluss:: | Schlauchklemm-Anschluss 8/12 |
max. Durchsatzleistung:: | 4 kg/h [mit Begrenzer 1 kg/h] |
Manometer:: | 0 - 16 bar[g] mit MAX-Schließkontakt |
Medium:: | Chlorgas |
Restdrucksicherung:: | 0,1 bar |
Funktion-2: | Überdruck der Gasbehälter auf Unterdruck [Vakuum]. |
Funktion-3: | Bei Wegfall des Betriebsvakuums schließt das Einlassventil und |
Funktion-4: | verhindert den Durchfluss. |
Funktion-5: | Geeignet für trockenes Chlorgas [Reinheit > 99,5%]. |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter