Pumping station HC
Available, delivery time: 4 days
Description:
The Lutz pumping station (HC) is suitable for low-viscosity, flammable and highly corrosive chemicals. Depending on the application, various motors are available which can be combined with the pumping station at any time. This gives you flexibility at all times and saves important resources.
- Also available in special immersion depths from 200 - 2500 mm
- Pumping unit equipped with Lutz original handwheel
- Used in the areas of fire and disaster control
Features & advantages
- Optionally with electric or compressed air drive
- No lubricants and therefore no contamination of the pumped medium by lubricants
- Approved in accordance with ATEX Directive 2014/34/EU, category 1/2
- Highly resistant carbon and ETFE shaft bearings
- Maintenance without special tools
- Sealing modules of the sealless (DL) pump can be replaced
Bearing (material): | ETFE / Kohle |
---|---|
Certification: | ATEX Richtlinie (ATEX Richtlinie 2014/34/EU) |
Conveyor wheel (material): | ETFE (ethylene-tetrafluorethylene copolymer) |
Conveyor wheel shape / drive type: | Radial-flow impeller |
Delivery head (up to max. mWS)*: | 26 |
Delivery rate (up to max. l/min)*: | 123 |
Density (up to kg/dm³): | 1.9 |
Drive shaft (material): | Hastelloy C (2.4610) |
Explosion protection: | Yes |
Gewinde (Zoll) außen: | 1 1/4" |
Immersion depth (mm): | from 1000 mm, from 1500 mm |
Pumped liquid temperature (max °C): | 120 |
Pumping unit material (material): | HC (Hastelloy C) |
Seal type: | Sealless (SL) |
Static seal (material): | FPM (fluororubber) |
Tauchrohrdurchmesser (max. mm): | 42 |
Typ: | HC 42-L-DL |
Viscosity (up to max. mPas)*: | 750 |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter