PowerCube
*Illustration may differ from the actual product
Description:
Diesel generators are currently mainly used at locations without a fixed power supply. The PowerCube was developed to ensure the power supply even without such a genset. The use of solar cells also offers the possibility of operating self-sufficient systems.
- Flexible and versatile in use
- Long runtime
- Compensation for unstable grid
Features & advantages
- Display with charge status and load
- Mains-independent power supply
- Ambient temperature: 0°C to 40°C (up to 50°C with power drop)
- Relative humidity: 20% to 90%
- Protection class: IP21
- Can be easily expanded to a permanent power source with solar panel via Plug&Play
Technical data
General:
- Ambient temperature: 0°C to 40°C (up to 50°C with power drop)
- Relative humidity: 20% to 90%
- Protection class IP21
- Weight: 50 kg
- Dimensions (l x w x h): 310 x 300 x 410 mm
Mains connection input:
- Voltage: 100 - 120V / 200 - 240V
- Frequency: 50 - 60 Hz
- cos ?: > 0.65 at 230 V AC
- Input current: 7A/115V AC, 3A/230V AC
- Inrush current: 60 A (cold start)
- Leakage current: < 3.5mA / 240V AC
Input connection solar panel:
- Voltage range: 17.3V - 43V
- Module current: 10 A
Output socket inverter:
- Voltage: 1~, 230V ± 10%,
- frequency: 50 Hz ± 1%,
- Continuous power 500 W
- Power output in % of continuous power: 120% - 150% for 10 seconds, 150% - 200% for 2 seconds
Load output, charge controller:
- Voltage: 24 V DC
- Current: 10 A
USB connection:
- Voltage: 5 V DC
- Current: 2.1 A
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter
Accessory Items
To enquire this product, please log in here.