Product information "MEMDOS LB"

MEMDOS LB - technology that makes waves!

The MEMDOS LB is a motorised diaphragm dosing pump that is used when no control system is required for constant dosing. Thanks to a robust tappet drive with manual or automatic power adjustment, the pumped media, e.g. acids, alkalis, precipitants and flocculants, are dosed reliably and accurately.

To adjust the dosing capacity, the stroke length can be adjusted mechanically or the speed of the three-phase motor can be controlled via a separate frequency converter. The MEMDOS LB is also available with a double diaphragm system on request.

Features & advantages

  • Capacity range 4 - 1020 l/h, up to 16 bar
  • Power supply 120 V, 230 V or 400 V
  • Material versions PVC, PP, PVDF and stainless steel
  • Stroke length infinitely adjustable from 0 - 100
  • Wide range of three-phase and alternating current motors
  • ATEX versions for zones 1 and 2 possible
  • Suitable for frequency converter operation
  • Double diaphragm system (optional)
  • Automatic stroke length adjustment (optional)
MATCHCODE: 0104L0020PMAC00002K2KP1EP1E
Produkt:: MEMDOS
Typ:: LB
Fördermenge:: 22 l/h bei 50 Hz - 26,4 l/h bei 60 Hz gegen max. 12 bar
Werkstoff Dosierkopf und Ventile:: PP
Leistungsverstellung:: Hublänge manuell einstellbar 0 - 100 %
Elektrischer Anschluss:: ohne Kabel
Elektrischer Antrieb:: 400 V 3ph 50 Hz 0,12 kW - 460 V 3ph 60 Hz 0,14 kW
Sauganschluss:: Schlauchklemm-Anschluss 6/9
Elektrische Optionen:: ohne
Saugventil:: DN4 Doppelkugel Keramik/PVDF/FPM [Kugel/Sitz/Dichtung]
Druckanschluss:: Schlauchklemm-Anschluss 6/9
Druckventil:: DN4 Doppelkugel Keramik/PVDF/FPM [Kugel/Sitz/Dichtung]
Werkstoff Sauganschluss:: PP
Werkstoff Druckanschluss:: PP

* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.

** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter