MAGDOS LB
MAGDOS LB - Simple dosing pump of the latest generation!
The MAGDOS LB solenoid-driven diaphragm dosing pump is a cost-effective alternative for simple, continuous dosing tasks. It is particularly suitable for water treatment and the process industry. The MAGDOS LB is available in seven performance ranges. Double ball valves ensure precise dosing. The dosing capacity can be adjusted continuously from 0 - 100 % via the stroke frequency of the dosing pump. The MAGDOS LB is a compact solution, reduced to the most important elements for reliable dosing.
Features & advantages
- Output range 0.36 - 13 l/h, up to 16 bar
- Wide-range power supply 100 - 240 V, 50/60 Hz, IP65
- Dosing head ventilation (plastic version)
- Suitable for wall and floor mounting
- Material versions PVC, PP, PVDF, stainless steel
- Dosing capacity continuously adjustable from 0 - 100
- CSA and UL certified
MATCHCODE: | 0102M0010BV001AD0D0V1ZV1Z0 |
---|---|
Produkt:: | MAGDOS |
Typ:: | LB |
Fördermenge:: | 0,76 l/h bei 16 bar - 1,1 l/h bei 8 bar |
Werkstoff Dosierkopf und Ventile:: | PVDF |
Leistungsverstellung:: | Hubfrequenz einstellbar 0 - 250 Hübe/min |
Steuereinheit:: | 100 - 240 V AC, 50/60 Hz |
Elektrischer Anschluss:: | 1,8 m Netzkabel mit Stecker, Europa [bei 230 V AC] |
Sauganschluss:: | Schlauchklemm-Anschluss-Set 4/6, 6/9 und 6/12 |
Saugventil:: | DN3 Doppelkugel PTFE/PVDF/FPM [Kugel/Sitz/Dichtung] |
Druckanschluss:: | Schlauchklemm-Anschluss-Set 4/6, 6/9 und 6/12 |
Druckventil:: | DN3 Doppelkugel PTFE/PVDF/FPM [Kugel/Sitz/Dichtung] |
Funktion-4: | Niveaueingang mit Hauptalarm |
Funktion-5: | oder Freigabeeingang für extern Start/Stop |
Funktion-6: | Status LED |
Werkstoff Sauganschluss:: | PVDF |
Werkstoff Druckanschluss:: | PVDF |
Dosierkopfanordnung:: | Bodenmontage |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter