MAGDOS LA
MAGDOS LA
The MAGDOS LA plays an important role in the reliable and precise dosing of liquids in process sequences and is available in seven performance ranges. Double ball valves ensure exact dosing. To adjust the dosing capacity, the stroke frequency can be adjusted manually or via an analogue signal (0/4 - 20 mA).
The compact dosing pump can be integrated into any dosing system in a very space-saving manner thanks to its minimal mounting surface and can also be installed in three different positions, upright or horizontal, without any additional aids. left or right orientated on the wall.
Features & advantages
- Output range 0.36 - 13 l/h, up to 16 bar
- Power supply 230 V ±10 %, 50/60 Hz, IP65 or 115 V ± 10 %, 50/60 Hz, IP65
- Dosing head ventilation (plastic version)
- Suitable for wall and floor mounting
- Material versions PVC, PP, PVDF, stainless steel
- Stroke frequency precisely adjustable with keypad
- Graphic display
- Analogue input 0/4 - 20 mA adjustable
- Level input with pre-alarm and main alarm
- Enable input for external start/stop
- CSA and UL certified
MATCHCODE: | 0102R0060DS011A2S2SW1EW1E0 |
---|---|
Funktionen:: | Hubfrequenz präzise mit Tastatur einstellbar |
Produkt:: | MAGDOS |
Typ:: | LA |
Fördermenge:: | 6,2 l/h bei 8 bar - 6,8 l/h bei 4 bar |
Werkstoff Dosierkopf und Ventile:: | 1.4571 |
Leistungsverstellung:: | Hubfrequenz einstellbar 0 - 180 Hübe/min |
Steuereinheit:: | 210 - 250 V AC, 50/60 Hz |
Elektrischer Anschluss:: | 1,8 m Netzkabel mit Stecker, Europa [bei 230 V AC] |
Sauganschluss:: | Schlauchklemm-Anschluss 6/9 |
Saugventil DN4:: | Doppelkugel 1.4401/1.4571/FPM [Kugel/Sitz/Dichtung] |
Druckanschluss:: | Schlauchklemm-Anschluss 6/9 |
Druckventil DN4:: | Doppelkugel 1.4401/1.4571/FPM [Kugel/Sitz/Dichtung] |
Funktion-2: | Grafikdisplay |
Funktion-3: | Analogeingang 0/4 - 20 mA einstellbar mit Anschlusskabel |
Funktion-4: | Niveaueingang mit Vor- und Hauptalarm |
Funktion-5: | Freigabeeingang für extern Start/Stop |
Funktion-18: | Pumpenstatus durch farbige Displaybeleuchtung |
Werkstoff Sauganschluss:: | Edelstahl/PVDF |
Werkstoff Druckanschluss:: | Edelstahl/PVDF |
Dosierkopfanordnung:: | Bodenmontage |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter