Gas pendulum system
Description:
Harmful gases and vapours remain practically in a closed system when filling or transferring hazardous liquids and ensure the necessary pressure equalisation themselves. The sealing plug adapts to different drum and container openings (D = 40-75 mm). Enables safe decanting, even into smaller containers, in conjunction with a dispensing nozzle. A non-return valve integrated into the vapour displacement line prevents the pump or container from being filled when the pump stops. Change the drum to prevent the gases from flowing back.
- Consisting of: Conical sealing plug, non-return valve for vapour return line, screw-in nipple with union nut and hose nozzle and hose clamps
Features & benefits
- Prevents the escape of harmful gases
- Protects against oxidising emissions
- For mobile operation
- Backflow of trapped gases when the pump stops is stopped by a non-return valve
Accessories group: | Mounts / Suspensions |
---|---|
Product group: | Fasspumpen / Containerpumpen |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter