Flow meter TS type VA10
Description:
The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures acids and alkalis, almost all solvents and highly flammable liquids precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the pump or the system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems.
- Optionally with quantity preselection (relay module)
- Examples of media: hydrochloric acid, nitric acid, styrene, petrol, acetone, etc.
- Mobile on a drum pump or with dispensing nozzle connection or stationary in plant construction
Features & advantages
- Measurement according to the wobble disc principle
- High measuring accuracy
- Variable display orientation
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 10 l/min- 100 l/min
- Simple operation
Ausführung/Ausstattung: | ohne Mengenvorwahl, with volume preselection |
---|---|
Connection: | Gewinde |
Einlass-Anschluss (Zoll): | 1 1/4" |
Frequency (Hz): | 50 |
Housing (material): | Stainless steel (1.4581/1.4571) |
Magnet (material): | PTFE (Polytetrafluorethylen) gekapselt |
Measuring accuracy calibrated**: | ± 1% |
Measuring chamber (material): | Edelstahl (1.4581/1.4571) |
Measuring range (up to max. l/min): | 100 |
Messprinzip: | Taumelscheibe |
Operating pressure (max. bar): | from 8 bar |
Outlet connection (inch): | 1 1/4" |
Protection class: | IP55 |
Pumped liquid temperature (max °C): | 80 |
Seals (material): | FEP |
Typ: | VA10, VA10 / RM10 230 V |
Viscosity (up to max. mPas)*: | 5000 |
Voltage (V): | 230 |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter