Flow meter TS type UN10 Ex

Product information "Flow meter TS type UN10 Ex"

Description:

The first flowmeter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents, acids, alkalis, highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the pump or system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems.

  • Optionally with volume preselection (relay module)
  • Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.
  • Mobile on a drum pump or with nozzle connection or stationary in plant construction

Features & advantages

  • Measurement according to the wobble disc principle
  • High measuring accuracy
  • Variable display orientation
  • Touchscreen display with self-explanatory, multilingual user interface
  • Measuring range from 10 l/min- 100 l/min
  • approved according to ATEX directive 2014/34/EU, category 2
Certification: ATEX Richtlinie (ATEX Richtlinie 2014/34/EU)
Connection: Gewinde
Design/equipment: ohne Mengenvorwahl
Explosion protection: Yes
Housing (material): PPS (Polyphenylensulfid)
Inlet connection (inch): 2"
Magnet (material): PPS (polyphenylene sulphide) encapsulated
Measuring accuracy calibrated**: ± 1%
Measuring chamber (material): LCP
Measuring principle: Swash plate
Measuring range (up to max. l/min): 100
Operating pressure (max. bar): 4
Outlet connection (inch): 1 1/4"
Protection class: IP55
Pumped liquid temperature (max °C): 60
Seals (material): FEP
Type: UN10 Ex
Viscosity (up to max. mPas)*: 2000

* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.

** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter

Accessory Items

Explosion protection
Swash plate
Battery
Flow meter TS type VA10 Ex
For solvents, acids, alkalis, oils and flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents, acids, alkalis, highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired quantity can be preselected with the quantity preselection (relay module) so that the pump or system switches off automatically after the selected quantity. This further simplifies and secures the operation of the systems. Optionally with volume preselection (relay module) Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc. Mobile on a drum pump or with nozzle connection or stationary in plant construction Features & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display orientation Touchscreen display with self-explanatory, multilingual user interface Measuring range from 10 l/min- 100 l/min approved according to ATEX directive 2014/34/EU, category 2
Explosion protection
Swash plate
Battery
Flow meter TS type LM10 Ex
For solvents, acids, alkalis, oils and flammable liquids
Description: The first flow meter with touchscreen display and backlighting impresses with its simple, needs-based display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables precise measurement of the volume flow and measures solvents and highly flammable liquids, oils and neutral media precisely, quickly and, above all, efficiently. Optionally, the desired volume can be preselected with the volume preselection (relay module) so that the pump or system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems. Optionally with volume preselection (relay module) Media examples: Methanol, petrol, isopropanol, paraffin, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc. Mobile on a drum pump or with nozzle connection or stationary in plant construction Features & advantages Measurement according to the wobble disc principle High measuring accuracy Variable display orientation Touchscreen display with self-explanatory, multilingual user interface Measuring range from 10 l/min- 100 l/min approved according to ATEX directive 2014/34/EU, category 2

Accessory Items

Explosion protection
Swash plate
Battery
Non-return valve
For solvents, acids, alkalis, oils and flammable liquids
Description: The non-return valve prevents the liquid from flowing back into the full hose system. Material: PTFE Properties & advantages Seals: FPM / FPM-FEP Opening pressure: 0.05 bar
Explosion protection
Swash plate
Battery
Solenoid valve
For solvents, acids, alkalis, oils and flammable liquids
Description: The 2/2-way solenoid valve seals off the air supply to the double diaphragm pump. It can be controlled via the relay module. Material: Brass / stainless steel / PVC The Ex versions include the mini CLIX®/eXLink® plug and a 5 m connection cable Features & advantages Seal: FPM / PTFE (Ex version) Connection type: 3/4 "IG Voltage: 230 V Frequency: 50 Hz
Explosion protection
Swash plate
Battery
Power supply unit Ex-NG10m
For solvents, acids, alkalis, oils and flammable liquids
Description: The power supply unit supplies power to the operating unit. When using a relay module, no additional power supply unit is required as the module includes the power supply function. For direct use in hazardous areas (Zone 1 & Zone 2) takes over the power supply for the complete flow meter system, e.g. for frequent filling processes or continuous operation of the meters Can be retrofitted to existing meter systems using modular technology Features & advantages Permanent power supply in hazardous areas Compact system possible due to mounting on basic meter No battery required in operating unit the power supply unit is supplied ready to plug in with 5 m connection cable and 3-pin Ex plug (CEAG) Frequency: 50 - 60 Hz
Explosion protection
Swash plate
Battery
Barrel pump connection
For solvents, acids, alkalis, oils and flammable liquids
Description: The drum pump connection is required to connect the ST 10 / SL10 flow meters to a drum and container pump. To connect the LM10 / UN 10 flow meter to a drum pump, the connection with the conductive drum pump connection in the PPS version is required. Materials PPO / PPS Features & advantages Connection: 1 1/4" female thread to 2" male thread Seals: FPM and FPM - FEP
Explosion protection
Swash plate
Battery
Communication module KM10K (complete version)
For solvents, acids, alkalis, oils and flammable liquids
Description: The communication module enables communication with other control units. Cable glands are integrated Features & benefits Analogue output (0-20mA, 4-20mA, 0-10V) Pulse and alarm output RS485 interface
Explosion protection
Swash plate
Battery
Control pen
For solvents, acids, alkalis, oils and flammable liquids