Flow meter HDO 080
Description:
The flow meter is a compact basic meter with a connection cable and plug for connection to an external control unit. Thanks to the rotating oval wheel meters and the magnets placed on the measuring wheels, it enables precise measurement of the volume flow and measures low-viscosity to highly viscous media such as acids, alkalis, mineral oils, hydrocarbons and solvents precisely, quickly and, above all, efficiently.
- Examples of media: paints, varnishes, mineral oils, acids, alkalis
Properties & advantages
- Measurement according to the oval gear principle
- High measuring accuracy due to overrun correction
- Low pressure losses in the system
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 0.25 l/min - 8.3 l/min
- Low frictional resistance
Ausführung/Ausstattung: | ohne Mengenvorwahl |
---|---|
Axle (material): | Edelstahl (1.4571) |
Connection: | Gewinde |
Connection thread inside (inch): | 1/4" |
Housing (material): | Edelstahl (1.4571) |
Measuring accuracy calibrated**: | ± 2,5 |
Measuring range (up to max. l/min): | 8,3 |
Measuring wheels (material): | Edelstahl (1.4571) |
Messprinzip: | Ovalrad |
Nominal diameter (DN): | 8 |
Operating pressure (max. bar): | 16 |
Pumped liquid temperature (max °C): | 80 |
Repeatability (%): | ± 0,03 |
Seals (material): | FPM (fluorinated rubber) |
Typ: | HDO 080 Niro/Niro |
Viscosity (up to max. mPas)*: | 1000 |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a liquid temperature of approx. 20 °C . The measurement is taken at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.
** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter